OSHA and ANSI Fall Protection for Petrochemicals and Refining

Or, give us a call: 1-888-936-0752

OSHA stands for the Occupational Safety and Health Administration, a federal agency that sets legal standards.

 ANSI stands for the American National Standards Institute. It is a private, not-for-profit trade association that publishes “best practices” to enable companies to meet or exceed OSHA regulations.

Both organizations want you to stay SAFE (Serious About Fall Elimination).

Refineries are complex structures, including distillation columns, storage tanks, flare stacks, cracking units, reactors, and various processing and building services equipment that need regular inspections and maintenance. Workers frequently operate at significant heights indoors and outdoors, navigating tall structures, ladders, elevated walkways, and rooftops.

These environments present substantial fall hazards, making stringent adherence to safety standards essential. Installing slip-resistant walkways, horizontal lifelines, tank anchors, and ever-versatile guardrails and even self-closing safety gates will help mitigate the risks and safeguard workers.

So, get a GRIP (Guardrails Reduce Injury Potential) to help prevent injuries in the petroleum and petrochemical refining industry.

REGULATIONS: OSHA Fall Protection Laws

OSHA standard 1910.28(b)(5)(i) mandates that employers must ensure that employees on a walking-working surface with an unprotected side or edge four (4) feet or more above a lower level are protected by a guardrail system, safety nets, or a personal fall arrest system (PFAS).

According to OSHA 1926.502(b), guardrail systems must meet several standards, notably:

  • Top rail between 39 and 45 inches above the walking-working level.
  • Mid-rail halfway between the top rail and the walking-working level.
  • Capable of withstanding (without failure) a force of at least 200 lbs. (890 N) applied at any point along the top edge within two (2) inches in any outward or downward direction.

For tasks involving fixed ladders, OSHA standard 1910.28(b)(9) states that employers must ensure that each employee using a ladder with a working height of more than 24 feet is equipped with a PFAS or ladder safety system.

OSHA 1910.140(c) has extensive requirements for installing and using personal fall protection equipment components. Horizontal lifelines and anchorages must be installed under the supervision of an OSHA-qualified person and be part of a PFAS that maintains a safety factor of at least two. Anchorages for PFAS must support at least 5,000 lbs. (22.2 kN) for each employee attached. Furthermore, employers must regularly inspect fall protection systems and ensure that all equipment meets OSHA’s stringent criteria.

STANDARDS: ANSI Fall Protection Best Practices

Developed with the American Society of Safety Professionals (ASSP), ANSI Z359.1-2020 is a widely recognized standard that provides guidelines for fall protection equipment and systems, ensuring they meet rigorous safety criteria. It covers “program management, system design, training, qualification and testing, equipment, and component and system specifications for the processes used to protect workers at height in a managed fall protection program.”

These guidelines offer detailed specifications for anchor points, lifelines, and rescue systems, ensuring higher safety for workers in high-risk environments like petroleum refineries. ANSI standards also emphasize the importance of designing fall protection systems tailored to specific work environments. For example, ANSI Z359.6 outlines requirements for ladder safety systems, which are particularly relevant in refineries where vertical access is often needed.

ANSI Z359.2-2023 emphasizes that eliminating or preventing exposure to fall hazards is the most effective control measure. To this end, it distinguishes between “passive” fall protection, a barrier system that prevents a fall (e.g., guardrails), and “active” fall protection, which directly involves the user (e.g., lifelines) designed to keep workers safe in the event of a slip and fall.

Passive fall protection is preferred because it protects multiple workers without training or wearing special equipment. Administrative controls are required where passive systems are not feasible or in place. These include installing active systems by a qualified person, providing certified training, and conducting regular equipment inspections

Implementing OSHA/ANSI Fall Protection in Petroleum Refineries

To comply with OSHA and ANSI standards, petroleum refineries must implement comprehensive fall protection measures tailored to their specific environments.

Guardrails – Constructed of strong, durable, and corrosion-resistant aluminum or galvanized steel, modular guardrail systems can be configured for site-specific needs and are installed without welding or drilling. Their versatility makes them ideal for mezzanines, loading docks, dangerous machinery, elevated walkways, stairs, work access platforms, and rooftops.

    • Permanent roof edge guardrails for flat and low-sloped roofs feature recycled PVC counterweight bases that do not penetrate the roof.
    • Temporary guardrails are ideal for short-term projects or maintenance tasks as they are easy to assemble, disassemble, and relocate as needed.

    Walkways – Rooftop and other elevated walkway systems feature anti-slip aluminum or nylon set in sturdy aluminum or galvanized steel frames for non-bounce stability. Treads are also self-draining to prevent the accumulation of water or slippery fluids. Crossover walkways enable workers to traverse obstructions (e.g., pipes, cables, conduits, ducts) or a change in level. Walkways and crossovers withstand harsh conditions and frequent use.

    Work Access Platforms – Safer and more efficient than ladders, work access platforms integrate slip-resistant walkway treads (for steps and decks) with pipe-fitted frames and guardrails to enable employees to reach heights and perform inspections, maintenance, repairs, and other tasks. They can be fitted with heavy-duty locking casters for portability.

    Lifeline Systems – Where guardrails are impractical, lifeline systems provide critical fall protection. They feature galvanized and stainless steel components and allow workers freedom of movement and a wide range of motion.

    • Engineered horizontal lifeline systems support up to three workers in spans up to 39 feet between anchorages. They are ideal for rooftops and extensive walkways.
    • Wall-mounted lifelines feature linear anchorages with energy absorbers mounted against a wall to provide continuous runs of travel restraint and fall arrest.
    • Overhead lifelines can accommodate up to three workers over single spans up to 200 feet. High-tension multiple spans up to 100 feet can support one or two users.
    • Vertical lifelines for scaling and descending ladders can be designed for virtually any ladder configuration and provide continuous protection over the entire system length.

    Tank Anchors – Working on or around large storage tanks presents unique fall hazards, especially where installing guardrails is not feasible. Tank anchors provide secure attachment points for personal fall arrest systems. Constructed of A570 or A607 grade steel with a coated finish appropriate to environmental conditions, they clamp onto tank flanges from 6 inches to up to 4 feet in diameter.

    Take the next step for safety.

    Fall protection at petroleum refineries is a multifaceted challenge that requires specialized solutions to adhere to OSHA regulations and ANSI standards. Compliant guardrails, slip-resistant walkways, safe access platforms, personal fall arrest lifeline systems, and tank anchors will enable businesses to protect their valued workers, improve efficiency, and meet regulations and standards.